Electric Control Globe Valve: Premium HVAC Flow Control SolutionsHigh-Performance Motorized Globe Valves for Residential, Commercial & Industrial Applications
Features of Electric Control Globe Valve
Our electric control globe valves combine advanced technology with robust construction to deliver superior performance, reliability, and energy efficiency across diverse HVAC applications.
Aluminum alloy housing with elegant appearance ensures durability while maintaining lightweight structure for easy installation and long-term reliability.
Compatible with cast iron, cast steel, and stainless steel valve bodies. Features equal percentage flow characteristics suitable for high-flow, high-pressure applications.
Electric hydraulic technology provides high precision control and rapid response speed, delivering exceptional energy efficiency and optimal system performance.
Rich actuator functions with valve position feedback, LED status display, and seamless integration with building automation systems for intelligent control.
Our Electric Control Globe Valve Models
Comprehensive range of electric control globe valves available in multiple sizes and configurations to meet your specific HVAC system requirements.
HVS Electric Control Valve – Globe Valve
Choosing the Right Electric Control Globe Valve
Choose the right electric control globe valve for your application by considering key factors such as system requirements, operating conditions, and control specifications.
Detailed Technical Specifications
| Category | Parameter Details |
|---|---|
| Applicable Media | Chilled water, hot water, saturated steam, thermal oil, clean water |
| Connection Type | Flange connection |
| Stroke | DN15-DN50: 20 mm |
| DN65-DN150: 40 mm | |
| Valve Body Material | Ductile iron, carbon steel, stainless steel |
| Valve Stem Material | Stainless steel |
| Seal Material | Stainless steel FEPM (silicon-free) |
| Nominal Pressure | PN25 |
| Media Temperature | -20°C to 220°C |
| Leakage Rate | 0 to 0.01% |
| Flow Characteristics | Linear / Equal percentage |
| Communication | 4-20mA / RS485 / M-Bus |
Uses and Applications of Electric Control Globe Valve
Electric control globe valves are essential components in modern HVAC systems, providing precise flow regulation across residential, commercial, and industrial applications for optimal comfort and energy efficiency.
Residential Heating & Cooling Systems
Ideal for single-family and multi-family residential applications, controlling water flow in heating circuits, air conditioning systems, and domestic hot water supply. Ensures consistent temperature control and energy savings in homes and apartments.
Commercial Building HVAC
Perfect for sophisticated air conditioning systems in modern office buildings, hotels, and retail spaces. Manages chilled water distribution, heating loops, and ventilation systems, maintaining optimal indoor climate while maximizing energy efficiency.
District Heating & Cooling Networks
Essential for large-scale district heating and cooling systems, regulating flow and temperature in distribution networks. Provides reliable operation in high-capacity applications with excellent control precision for community-wide climate control solutions.
Industrial Process Control
Widely used in high-precision industrial HVAC systems and manufacturing facilities requiring accurate temperature and flow control. Suitable for high-flow, high-pressure differential applications in factories, clean rooms, and specialized production environments.
Positive Displacement Water Meters: How They Work
A worn positive displacement water meter doesn’t fail. It keeps turning, keeps billing, and quietly under-reports. A burst main gets…
Choosing a 4-20 mA Signal Isolator for Pressure Transmitters: Ground Loops and Active/Passive Inputs
Choose a 4-20 mA signal isolator by matching the power roles on both sides, the required isolation boundaries, and each…
NAMUR NE43 for Pressure Transmitters: Fault Current vs Measurement Saturation
NAMUR NE43 separates failure signals from pressure readings in an analog current loop. At saturation, the transmitter has reached its…
Maintenance and Care for Electric Control Globe Valve
Conduct periodic visual inspections to check for leaks, corrosion, or damage. Clean external surfaces and ensure LED indicators function properly. Verify valve position feedback accuracy and test manual override operation quarterly to maintain system reliability.
Inspect actuator components and lubricate moving parts according to manufacturer guidelines. Check electrical connections for tightness and corrosion. Test control signals (4-20mA/RS485) and verify proper communication with building automation systems for consistent performance.
Monitor flow characteristics, leakage rates, and response times regularly. Check for unusual noise or vibration during operation. Verify seal integrity and valve seat condition annually. Replace worn components promptly to prevent system inefficiency and ensure continuous optimal operation.


Why Choss Our Electric Control Globe Valve
Frequently Asked Questions (FAQs)
Find answers to common questions about electric control globe valves, including technical specifications, installation, operation, and maintenance information.
01
01
An electric control globe valve is a motorized valve that regulates fluid flow in HVAC systems using electric actuators. It provides precise control of water, steam, or thermal oil flow through automated positioning based on control signals from building automation systems.
02
02
Our electric control globe valves are available in sizes ranging from DN15 to DN150. Smaller sizes (DN15-DN50) feature 20mm stroke, while larger sizes (DN65-DN150) have 40mm stroke for optimal flow control across various applications.
03
03
These valves are suitable for chilled water, hot water, high-temperature hot water, saturated steam, thermal oil, and clean water. They operate effectively in temperature ranges from -20°C to 220°C with PN25 nominal pressure rating.
04
04
Our valves support multiple communication protocols including 4-20mA current signal output, RS485, and M-Bus. They’re compatible with various control signals (DC 0-10V, 4-20mA, or 0-1000Ω) for seamless integration with most building management systems.
05
05
Our electric control globe valves maintain an exceptionally low leakage rate of 0 to 0.01%, ensuring minimal energy loss and optimal system efficiency. This tight shut-off capability reduces operational costs and improves overall system performance.
06
06
Valve bodies are available in ductile iron, carbon steel, or stainless steel. Valve stems, plugs, and seats are made of stainless steel for corrosion resistance. Seals use stainless steel FEPM material (silicon-free) for durability and reliability.
07
07
With proper maintenance and operation within specified parameters, our valves offer extended service life spanning many years. Rigorous testing ensures exceptional quality and durability. Regular inspections and preventive maintenance maximize longevity and performance.