Advanced IoT Data Collection Terminal for Pipeline MonitoringHigh-Performance Data Acquisition Solution with NB/4G Connectivity


Features of IoT Data Collection Terminal
Designed and manufactured by Beijing Black Ant, this intelligent terminal delivers comprehensive monitoring capabilities for heating systems, HVAC pipelines, and industrial processes with unmatched accuracy and convenience.
Temperature accuracy reaches ±0.3℃ while pressure sensors achieve ±0.5% FS precision, customizable to ±0.25% FS. Advanced digital circuitry ensures strong RF and electromagnetic interference resistance, maintaining long-term stability better than ±0.1% FS per year.
Supports multiple signal protocols including M-Bus, RS485, 4G, and LoRa connectivity. Seamlessly integrates with various automation control systems and remote monitoring platforms, enabling real-time data transmission without distance limitations through NB/4G networks.

Engineered to withstand extreme conditions including high temperatures, low temperatures, and corrosive environments. Perfectly suited for coal mining, chemical processing, heating systems, oil refining, food processing, and agricultural applications across diverse industrial sectors.
Temperature sensors feature patch-type mounting requiring no pipe cutting or welding, allowing installation without interrupting pipelines. Battery-powered wireless models eliminate communication wiring needs. Ultra-low power consumption under 2.5uA ensures battery life exceeding 6 years with easy replacement.
Our IoT Data Collection Terminal Models
Explore our range of data collection terminals engineered for diverse monitoring needs, offering multiple communication protocols and sensor configurations to match your specific application requirements.

HGI IoT Data Collection Terminal
Benefits of Using IoT Data Collection Terminal
Implementing our IoT data collection terminals transforms your pipeline monitoring operations, delivering measurable improvements in efficiency, cost savings, and system reliability across all industrial applications.
Detailed Technical Specifications
| Category | Basic Model |
|---|---|
| Uplink Communication | 4G/LoRa/M-Bus/RS485 |
| Temperature Range | -10℃~+95℃ |
| Temperature Accuracy | ±0.3℃ |
| Power Supply | Lithium Battery |
| Standby Current | Less than 2.5 uA |
| Operating Voltage | 3.6V |
| Battery Capacity | 19000mAh (Default), Shell supports up to 38000mAh |
| Protection Rating | IP68 |
| Collection Cycle | Default 30 minutes ~ 30 days, Customizable |
| Upload Cycle | Default 30 minutes ~ 30 days, Customizable |
| Shell Material | PVC |
| Dimensions | 160mm103mm56mm |
| Mounting Method | Wall-mounted |
| Supported Sensors | Maximum support 4-channel temperature / 2-channel pressure, Dual temperature dual pressure available |
| Sensor Installation | Temperature sensor: Patch-type or insertion-type; Pressure sensor: Insertion-type |
Uses and Applications of IoT Data Collection Terminal
Our versatile terminals serve diverse industrial sectors, providing critical monitoring capabilities for heating systems, manufacturing processes, and environmental control applications where accurate temperature and pressure data drives operational decisions.
District Heating Systems
Monitors secondary network pipelines in residential buildings and unit-level distribution systems. Tracks supply and return temperatures alongside pressure differentials, optimizing heat distribution efficiency and identifying system imbalances for centralized heating networks.
HVAC and Air Conditioning
Controls commercial and industrial climate systems by measuring refrigerant pressures and cooling water temperatures. Ensures optimal performance of chillers, cooling towers, and distribution loops while preventing equipment damage from abnormal operating conditions.
Chemical and Oil Refining
Safeguards process pipelines in refineries and chemical plants where precise temperature and pressure monitoring prevents hazardous conditions. Corrosion-resistant design withstands aggressive media while maintaining measurement accuracy in demanding industrial environments.
Food Processing and Agriculture
Monitors sterilization temperatures, pasteurization processes, and controlled environment agriculture systems. Ensures food safety compliance and optimal growing conditions in greenhouses, livestock facilities, and processing plants through reliable continuous monitoring.
Positive Displacement Water Meters: How They Work
A worn positive displacement water meter doesn’t fail. It keeps turning, keeps billing, and quietly under-reports. A burst main gets…
Choosing a 4-20 mA Signal Isolator for Pressure Transmitters: Ground Loops and Active/Passive Inputs
Choose a 4-20 mA signal isolator by matching the power roles on both sides, the required isolation boundaries, and each…
NAMUR NE43 for Pressure Transmitters: Fault Current vs Measurement Saturation
NAMUR NE43 separates failure signals from pressure readings in an analog current loop. At saturation, the transmitter has reached its…
Maintenance and Care for IoT Data Collection Terminal
Conduct quarterly visual inspections to check housing integrity and sensor connections. Verify data transmission quality through monitoring platform. Clean exterior surfaces to remove dust and debris, ensuring proper ventilation around the device for optimal performance.
Monitor battery voltage levels through system alerts. Replace batteries every 6+ years or when low-voltage warnings appear. Use only manufacturer-approved lithium batteries. Simple replacement procedure requires no special tools, minimizing downtime during battery service operations.
Annual verification recommended for critical applications, though exceptional stability of ±0.1% FS per year reduces calibration frequency. Compare readings against reference standards. Contact technical support if measurements drift beyond specified accuracy ranges for recalibration services.


Why Choose Our IoT Data Collection Terminal
Frequently Asked Questions (FAQs)
Find answers to common questions about our IoT data collection terminals, covering technical specifications, installation procedures, and operational considerations to help you make informed decisions.
01
01
The basic model supports up to 4 temperature sensors or 2 pressure sensors. Dual temperature dual pressure configuration is also available, allowing simultaneous monitoring of both parameters on the same terminal.
02
02
With ultra-low power consumption below 2.5uA, the lithium battery provides over 6 years of operation. The battery is easily replaceable without special tools, and the housing supports up to 38000mAh capacity for extended applications.
03
03
Yes, the terminal operates reliably in temperatures ranging from -10℃ to +95℃. It’s designed to withstand high temperature, low temperature, and corrosive environments across various industrial applications.
04
04
The terminal supports multiple protocols including 4G, LoRa, M-Bus, and RS485, allowing flexible integration with various automation control systems and remote monitoring platforms based on your specific requirements.
05
05
Installation is straightforward. Temperature sensors use patch-type mounting that requires no pipe cutting or welding. Wireless models eliminate communication wiring needs. The wall-mounted design allows quick deployment without interrupting existing pipelines.
06
06
The terminal features IP68 protection rating, providing complete protection against dust ingress and water immersion. This ensures reliable operation in outdoor, underground, and harsh industrial environments.
07
07
Thanks to exceptional long-term stability of ±0.1% FS per year, calibration frequency is minimal. Annual verification is recommended for critical applications, but many installations operate reliably for extended periods without recalibration.